forked from Rockachopa/Timmy-time-dashboard
@@ -37,6 +37,7 @@ from dashboard.routes.db_explorer import router as db_explorer_router
|
||||
from dashboard.routes.discord import router as discord_router
|
||||
from dashboard.routes.experiments import router as experiments_router
|
||||
from dashboard.routes.grok import router as grok_router
|
||||
from dashboard.routes.energy import router as energy_router
|
||||
from dashboard.routes.health import router as health_router
|
||||
from dashboard.routes.hermes import router as hermes_router
|
||||
from dashboard.routes.loop_qa import router as loop_qa_router
|
||||
@@ -673,6 +674,7 @@ app.include_router(matrix_router)
|
||||
app.include_router(tower_router)
|
||||
app.include_router(daily_run_router)
|
||||
app.include_router(hermes_router)
|
||||
app.include_router(energy_router)
|
||||
app.include_router(quests_router)
|
||||
app.include_router(scorecards_router)
|
||||
app.include_router(sovereignty_metrics_router)
|
||||
|
||||
121
src/dashboard/routes/energy.py
Normal file
121
src/dashboard/routes/energy.py
Normal file
@@ -0,0 +1,121 @@
|
||||
"""Energy Budget Monitoring routes.
|
||||
|
||||
Exposes the energy budget monitor via REST API so the dashboard and
|
||||
external tools can query power draw, efficiency scores, and toggle
|
||||
low power mode.
|
||||
|
||||
Refs: #1009
|
||||
"""
|
||||
|
||||
import logging
|
||||
|
||||
from fastapi import APIRouter, HTTPException
|
||||
from pydantic import BaseModel
|
||||
|
||||
from config import settings
|
||||
from infrastructure.energy.monitor import energy_monitor
|
||||
|
||||
logger = logging.getLogger(__name__)
|
||||
|
||||
router = APIRouter(prefix="/energy", tags=["energy"])
|
||||
|
||||
|
||||
class LowPowerRequest(BaseModel):
|
||||
"""Request body for toggling low power mode."""
|
||||
|
||||
enabled: bool
|
||||
|
||||
|
||||
class InferenceEventRequest(BaseModel):
|
||||
"""Request body for recording an inference event."""
|
||||
|
||||
model: str
|
||||
tokens_per_second: float
|
||||
|
||||
|
||||
@router.get("/status")
|
||||
async def energy_status():
|
||||
"""Return the current energy budget status.
|
||||
|
||||
Returns the live power estimate, efficiency score (0–10), recent
|
||||
inference samples, and whether low power mode is active.
|
||||
"""
|
||||
if not getattr(settings, "energy_budget_enabled", True):
|
||||
return {
|
||||
"enabled": False,
|
||||
"message": "Energy budget monitoring is disabled (ENERGY_BUDGET_ENABLED=false)",
|
||||
}
|
||||
|
||||
report = await energy_monitor.get_report()
|
||||
return {**report.to_dict(), "enabled": True}
|
||||
|
||||
|
||||
@router.get("/report")
|
||||
async def energy_report():
|
||||
"""Detailed energy budget report with all recent samples.
|
||||
|
||||
Same as /energy/status but always includes the full sample history.
|
||||
"""
|
||||
if not getattr(settings, "energy_budget_enabled", True):
|
||||
raise HTTPException(status_code=503, detail="Energy budget monitoring is disabled")
|
||||
|
||||
report = await energy_monitor.get_report()
|
||||
data = report.to_dict()
|
||||
# Override recent_samples to include the full window (not just last 10)
|
||||
data["recent_samples"] = [
|
||||
{
|
||||
"timestamp": s.timestamp,
|
||||
"model": s.model,
|
||||
"tokens_per_second": round(s.tokens_per_second, 1),
|
||||
"estimated_watts": round(s.estimated_watts, 2),
|
||||
"efficiency": round(s.efficiency, 3),
|
||||
"efficiency_score": round(s.efficiency_score, 2),
|
||||
}
|
||||
for s in list(energy_monitor._samples)
|
||||
]
|
||||
return {**data, "enabled": True}
|
||||
|
||||
|
||||
@router.post("/low-power")
|
||||
async def set_low_power_mode(body: LowPowerRequest):
|
||||
"""Enable or disable low power mode.
|
||||
|
||||
In low power mode the cascade router is advised to prefer the
|
||||
configured energy_low_power_model (see settings).
|
||||
"""
|
||||
if not getattr(settings, "energy_budget_enabled", True):
|
||||
raise HTTPException(status_code=503, detail="Energy budget monitoring is disabled")
|
||||
|
||||
energy_monitor.set_low_power_mode(body.enabled)
|
||||
low_power_model = getattr(settings, "energy_low_power_model", "qwen3:1b")
|
||||
return {
|
||||
"low_power_mode": body.enabled,
|
||||
"preferred_model": low_power_model if body.enabled else None,
|
||||
"message": (
|
||||
f"Low power mode {'enabled' if body.enabled else 'disabled'}. "
|
||||
+ (f"Routing to {low_power_model}." if body.enabled else "Routing restored to default.")
|
||||
),
|
||||
}
|
||||
|
||||
|
||||
@router.post("/record")
|
||||
async def record_inference_event(body: InferenceEventRequest):
|
||||
"""Record an inference event for efficiency tracking.
|
||||
|
||||
Called after each LLM inference completes. Updates the rolling
|
||||
efficiency score and may auto-activate low power mode if watts
|
||||
exceed the configured threshold.
|
||||
"""
|
||||
if not getattr(settings, "energy_budget_enabled", True):
|
||||
return {"recorded": False, "message": "Energy budget monitoring is disabled"}
|
||||
|
||||
if body.tokens_per_second <= 0:
|
||||
raise HTTPException(status_code=422, detail="tokens_per_second must be positive")
|
||||
|
||||
sample = energy_monitor.record_inference(body.model, body.tokens_per_second)
|
||||
return {
|
||||
"recorded": True,
|
||||
"efficiency_score": round(sample.efficiency_score, 2),
|
||||
"estimated_watts": round(sample.estimated_watts, 2),
|
||||
"low_power_mode": energy_monitor.low_power_mode,
|
||||
}
|
||||
Reference in New Issue
Block a user